Life Science
Science Imaging
Product Info
Image data archives
Software
Technical Info
Application notes
Imaging Plate
Brochures
Nucleic Acid Isolation
Product Info
Isolation Kits
Application Guides
Brochures
Clinical Chemistry Analyzer
Product Info
Slides
Brochures
How to contact us
Life Science Site Map
JAPANESE
ACCESSORIES
Imaging Plate
BAS-SR2040
BAS-SR2025
size: 20 x 40cm
20 x 25cm
BAS-TR2040
BAS-TR2025
size: 20 x 40cm
20 x 25cm
BAS-MS2025
BAS-MS2040
BAS-MS2325
BAS-MS2340
BAS-MS3543
size: 20 x 25cm
20 x 40cm
23 x 25cm
23 x 40cm
35 x 43cm
BAS-TR2040
BAS-TR2025
size: 20 x 40cm
20 x 25cm


IP Cassette
size: 20 x 40cm
20 x 25cm
23 x 40cm
23 x 25cm
40 x 43cm


FLA-9000 Accessories
FLUOR Stage, IP Stage, MULTI Stage
From left to right:

FLUOR Stage
(with optional gel stopper)
A glass plate of 40x46cm can be used for fluorescence detection, digitizing function and chemiluminescence detection.

IP Stage
A magnetic stage holds the IP with a soft ferrite layer of any size up 40x46cm.

MULTI Stage
(with optional microtiter plate holder which can hold up to six microtiter plates)
Large size polyacrylamide gel plate can be measured with the glass.
Filters
B390 (IP)
LPB (510LP), LPG (575LP), LPR (665LP)
BPB (530DF20), BPG (570DF20), BPFR700 (R715), BPFR800 (R810)
DBR (530DF20 / 665LP), DGR (570DF20 / 665LP)
BAS-MS 3543
High sensitivity and waterproof MS type IP appeared in 350x430mm size. Corresponding IP cassette is 400x430mm in size, and is the size which two 200x400mm IP can be exposed simultaneously.


FLA-5100 Accessories
FLUOR Stage, IP Stage, MULTI Stage
From left to right:

FLUOR Stage
(with optional gel stopper)
A glass plate of 40x46cm can be used for fluorescence detection, digitizing function and chemiluminescence detection.

IP Stage
A magnetic stage holds the IP with a soft ferrite layer of any size up 40x46cm.

MULTI Stage
(with optional microtiter plate holder which can hold up to six microtiter plates)
Large size polyacrylamide gel plate can be measured with the glass.
BAS-MS 3543
High sensitivity and waterproof MS type IP appeared in 350x430mm size. Corresponding IP cassette is 400x430mm in size, and is the size which two 200x400mm IP can be exposed simultaneously.


FLA-8000 Accessories
Slide Carrier
Up to 5 glass slides can be set. Allowance for the size of the slide is very widely designed. Focusing of the optics is set on the surface of the glass slide. By setting the software at Slide mode, 5 slides can be imaged for all the wavelength equipped in the FLA-8000 by one click.
Gel Carrier
Up to 2 mini-gel (51x59mm) can be set. For example, agarose gel for checking the PCR products before hybridization can be applied. Focusing of the optics is set at 1 mm above the glass platen. By setting the software to Gel mode, 2 gels can be imaged at 100 um pixel size.
IP Carrier
A special size (85x127mm) imaging plate was prepared for FLA-8000, namely BAS-SR0813. IP carrier is a magnetic plate to stick the IP, which has soft ferrite layer. As the sensitivity of FLA-8000 is designed to be higher at Green-Red regions, the blue (390nm) photostimulated luminescence of IP detection is lower than other FLA systems or BAS systems.


FLA-7000 Accessories
PMT 1 (Bi-Alkali)
PMT 2 (Multi-Alkali)
473nm Laser
532nm Laser
635nm Laser
670nm Laser
Y520 Filter
O580 Filter
R670 Filter
R710 Filter
B390 Filter (for IP)
IP Stage
FLUOR stage (with Fluorescent Board)
Membrane weight
Back