LAS-3000

mainimage

The LAS-3000 imaging system combines new CCD camera technology with a simplified user interface to provide significantly improved system sensitivity with a wide range of modularities.


Sales of this product have been discontinued.

Features

  • Improved sensitivity and resolution
  • Improved versatility
  • Improved user interface
  • Improved design

Features

This system is especially suitable for Western blot analysis.High sensitive chemiluminescent detection was designed to compete with the X-ray films. Image acquire and digitize can capture both chemiluminescence and digitized marker image by one click.

Improved sensitivity and resolution

New Super CCD Area Type Imaging Chip

This system is especially suitable for Western blot analysis.High sensitive chemiluminescent detection was designed to compete with the X-ray films. Image acquire and digitize can capture both chemiluminescence and digitized marker image by one click.
New Super CCD Area Type Imaging Chip - The higher sensitivity of Fujifilm's new CCD provides improved faint-light image capture with outstanding image clarity. The new chip contains 3.2M pixels of which 3.15M contribute to actual imaging. The increased pixel size results from the use of octagonal-shaped photodiodes, which capture a great deal of light. The superior image sensing capability of the new chip results in ultra-high resolution image files of up to 6.3M pixels (3,072 x 2,048 pixels).

Super CCD

By rotating pixels 45 degrees to form an interwoven layout, the Super CCD's pixel pitch in the horizontal and vertical directions is narrower than in the diagonal direction, achieving higher horizontal and vertical resolution.

Conventional CCD

With conventional interline CCDs, pixel pitch in the diagonal direction is narrower than in the horizontal and vertical directions, resulting in higher diagonal resolution.

New Binning Mode

The LAS-3000 features a new binning mode, which allows users to effectively increase the pixel size and, therefore, the imaging sensitivity of the system.
Additionally, the process significantly enhances the signal-to-noise ratio. The system allows four binning settings: 1x2 (standard), 2x4 (high), 4x8 (super) and 8x16 (ultra). Images obtained in the binning mode are further enhanced by software-based pixel supplement to compensate for any loss in resolution.

The binning mode of the LAS-4000 allows researchers to select from four binning settings to enhance both imaging sensitivity and image resolution. With the Image Reader Pro software, High resolution, High binning, Super binning and Ultra binning images can be obtained in addition to the standard High Super and Ultra images.

Exposure Options

The extremely fast, electronically cooled, high-resolution camera component allows long exposure times in any laboratory setting. Exposures can be set from 1/100th of a second to 30 hours to meet a wide range of imaging conditions. The 30-hours exposure function allows over-night exposures on very dark images.

Improved versatility

New Filter Options

A 5-position filter turret is mounted in front of the lens, which allows convenient, electrically controlled filter selection in less than ten seconds. With Image Reader Lite software, the user has control over three standard filters (605DF40 for EtBr, Y515 for SYBR® Green and 510DF10 for GFP), a fourth filter position for chemiluminescence and a fifth user-specified filter for fluorescence. With Image Reader Pro software, the user has full control over five filter types and positions. Other than the above, 575 DF20 filter was prepared for green LED and R670 filler was prepared for red LED.

Additional Light Sources

The number of light sources on the LAS-3000 system has been increased to six, including UV transilluminator, white transilluminator, blue epi-illuminator and white epi-illuminator, green epi-illuminator and red epi-illuminator.With Image Reader Lite software, the user has control over four light sources (UV trans-illuminator, white trans-illuminator, blue epi-illuminator, and white epi-illuminator). With Image Reader Pro software, the user has control over all the six light sources (see above, plus green epi-illuminator and red epi-illuminator)

Sampling Convenience

The LAS-3000 accommodates samples up to 25 x 25cm in size with an optional wide view lens. Various types of trays are prepared such as an EPI Tray III for chemiluminescence and epi-illuminator, a DIA Tray III for UV trans-illuminator , a white-DIA Tray for white trans-illuminator such as CBB stained gel, and a non-parallax (NP) Tray for up to two titer plates. The NP tray includes a Fresnel lens located between the titer plate and the lens, which eliminates parallax in each of the 96 titer plate wells. NP Tray is designed for the detection of chemiluminescence.

Improved user interface

Simplified User Interface

The system functions of the LAS-3000 are controlled remotely through either a Mac™ or Windows® software application via a standard USB interface.
Image capture and analysis software is provided. The newly simplified user interface allows researchers to spend more time in research and less time in system integration and maintenance.

Light-tight operation

The light-tight dark box affords highly sensitive imaging from a variety of light sources in an ordinary lab. After placing the sample tray in the dark box and closing the light-tight door, all imaging functions are controlled remotely from the PC. With the keyboard and monitor, the researcher conveniently adjusts focus, selects the appropriate filter and sets the exposure to capture the image.

Improved design

Specifications

Image Capturing Unit (Camera Head and Controller)

CCD chip Fujifilm Super CCD Area Type chip
Number of Pixels 3.2 M pixels
Pixel Size 10.75 x 10.75µm
Cooling Peltier
Cooling temperature -30°C (when the room temperature is below 28°C)
-35°C (when the room temperature is below 20°C)
Focusing Power focusing; remote and preset control
Exposure time 1/100 second to 30 hrs (pre-set menu or manual input)
Dynamic range 4 orders of magnitude
Gradation 16 bits (65,536 gray levels)
Image size 12.6MB Max.; 49.2KB Min.
Maximum sample size 25 x 25cm (wide view lens); 14 x 21cm (Fujinon VRF43LMD lens)
Binning 1x2, 2x4, 4x8, and 8x16 pixels
Interface USB1.1

Software

Image capture Fujifilm Image Reader (Mac™ and Windows®)
Image analysis Fujifilm Image Gauge (Mac™); Fujifilm MultiGauge (Windows®)

Dimensions and Weights

Camera head 180 (W) x 170 (H) x 250 (D)mm  3.4kg
Dark Box IV 510 (W) x 730 (H) x 480 (D)mm  49.0kg

Analyzing Unit

Operating system Windows® XP or Mac™ OS 9.2.2, X.2, X.3

Applicable Reagents and/or Samples

Chemiluminescence CDP-Star®, ECL™, ECL Plus™, ECL Advance™, Lumi-Light Plus, Renaissance™, Bright-Star™, SuperSignal®, ImmunoStar, CSPD®
Fluorescence Blue LED SYBR® Green I & II, SYBR® Gold, SYPRO® Ruby, SYPRO® Orange, SYPRO® Tangerine, FITC, FAM™, EGFP, ECFP, AttoPhos™
Green LED SYPRO® Red, Cy™3, TMRA™, ROX™, HEX™, Alexa Fluor®532, Alexa Fluor®546,Deep Purple, Pro-Q™Diamond, Rhodamine Red™, BODIPY®576/589, NED™, R-phycoerythrin, RFP, HNPP
Red LED Alexa Fluor®633, Alexa Fluor®635, Alexa Fluor®647, Cy™5, BODIPY®650/665, DiD, TOTO®-3, DDAO phosphate,
UV Eidium Bromide, SYPRO®Rose, EtBr
Digitize CBB/silver stained gel (Trans-illuminator)
NBT/BCIP stained membrane (EPI-illuminator)

Intelligent Dark Box IV

Blue-EPI-illuminator for fluorescence** Blue LED (460nm)
Green-EPI-illuminator for fluorescence (option)** Green LED (520nm)
Red-EPI-illuminator for fluorescence (option)** Red LED (630nm)
EPI-illuminator for documentation White-light source
White trans-illuminator for documentation of stained gels and Autoradiographic films White LED
UV trans-illuminator*** UV-light source (312nm)
Filter turret Five positions

Lens

High sensitivity lens (FUJINON VRF43LMD)

F-number 0.85
Focal length 43mm
Focus Remote power focusing
Mount Bayonet

Wide view lens

F-number 2.0
Focal length 24mm
Focus Manual
Mount Adapter to Nikon F
  • * No license is granted for use of AttoPhos™ to detect nucleic acid on a nylon membrane.
  • ** White-light source for EPI-illumination is built-in in the same unit.
  • *** No license is granted for pre-labeling gel electrophoresis method with the UV transilluminator.

Image Data

Chemiluminescent Western Blot using ECL™
Sample
Dilution series of mouse IgG
Binning mode
High Resolution
Exposure time
30 sec
Fluorescent gel electrophoresis with SYBR® Green I
Sample
Agarose gel electrophoresis of diluted series of lambda DNA/Hind III
Light source
Blue LED epi-illuminator
Filter
Y515-Di
Binning mode
High Resolution
Exposure time
20 sec