FCR PRIMA T

Extremely fast processing in a compact body streamlines diagnosis

This compact table-top reader unit has outstandingly high-speed processing to challenge the common misconception of CR.

Features

  • High-speed processing
  • Space-saving design
  • Stable high-quality images

Download Documents

Adobe® Reader® is required to see the PDF data.

Note

  • In some countries, regulatory approval may be required to import medical devices.
  • For the availability of these products, please contact your local sales representatives.

Features

High-speed processing

FCR PRIMA T is a table-top reader unit which boasts a world-class high processing speed of 57 IPs / hour. With the optional Upgrade Kit this speed can be increased still further to 67 IPs / hour. As with all Fujifilm equipment FCR PRIMA T is easy to operate. It will help reduce patient waiting time and greatly increase the efficiency of examination workflow.

[Image]High-speed processing

Space-saving design

FCR PRIMA T, with its light, compact, table top design is Fujifilm's first FCR model of this type. It can be placed on a desk or shelf or anywhere space is limited. As this is a fully digital reader neither a darkroom nor automatic processor are required. FCR PRIMA T can always be installed in the space vacated by a chemistry based processor.

[Image]Space-saving design

Stable high-quality images

Although this is a compact machine its excellent image quality is the same as that produced by the rest of the FCR range. Image Intelligence™, Fujifilm's proprietary image processing technology, enhances image contrast and sharpness, without any deterioration of details. FCR PRIMA T supports accurate diagnosis by offering stable and optimized image quality.

[Logo] Image Intelligence™
  • MFP (Multi-Frequency Procesing)*

Enhances FCR images. All diagnostic scopes will be enhanced except for noise.

  • * Optional Software
[Image] MFP (Multi-Frequency Procesing)
  • FNC (Flexible Noise Control)

Provides a non-grainy image by mainly isolating and suppressing the noise for the signal

[Image] FNC (Flexible Noise Control)
  • GPR (Grid Pattern Removal)

Removes the stationary grid patterns thus preventing Moiré from being generated resulting in easier diagnosis.

[Image] GPR (Grid Pattern Removal)

System Configuration

[Image] System Configurations

All-in-one workstation

FCR PRIMA Console and FCRView are an all-in-one viewers that turns your desktop into a multi-function workstation for all your radiographic imaging needs. You can initiate exposures, process and print your studies and backup patient information all within a single unit.

[Image] All-in-one workstation

Specifications

Standard Components FCR PRIMA T Image Reader (Model: CR-IR 392)
AC power cord
Other System Components IP cassette type CC
FCR PRIMA Console, FCRView
Dry Imager: DRYPIX PRIMA, DRYPIX 2000, 7000, Plus
Supplies
Imaging Plate ST-VI:
35 × 43 cm (14″ × 17″), 35 × 35 cm (14″ × 14″), 10″ × 12″, 8″ × 10″,
24 × 30 cm, 18 × 24 cm, 15 × 30 cm (Variation)
IP Cassette Type CC:
35 × 43 cm (14″ × 17″), 35 × 35 cm (14″ × 14″), 10″ × 12″, 8″ × 10″,
24 × 30 cm, 18 × 24 cm, 15 × 30 cm (Variation)
Time Required for IP Feed / Load Min. 64 sec. (Min. 54 sec.)*
Processing Capacity Up to 57 IPs / hr. (Up to 67 IPs / hr.)*
Reading Specification 10 pixels / mm, 5 pixels / mm**
Time to Start on Display Min. 33 sec.
Time to Print on DRYPIX PRIMA Approx. 165 sec. (Approx. 155 sec.)** in case of 35 × 43 cm
Number of Stacker 1
Network 10 Base T / 100 Base TX
Dimensions (W × D × H) 560 × 540 × 392 mm (22″ × 21″ × 15″)
Weight 39 kg (86 lbs.)
Power Supply Conditions Single phase 50 - 60 Hz
AC 120 - 240 V ±10% 1.9 A (max)
Environmental Conditions
Operating Conditions:
  • Temperature: 15-30 °C
  • Humidity: 15-80% RH (No dew condensation)
  • Atmospheric pressure: 750-1060 hPa
  • This equipment is a Class 1 laser product (IEC60825-1:2001).
  • * When using the Upgrade Kit
  • ** When using the Upgrade Kit and in the High Speed mode
[Image] Dimensions / Imaging Plate ST-VI / IP Cassette Type CC