Quick to detect risks, and friendly to users — devotion to accurate NDT that supports industries
Fusion of Fujifilm's advanced technologies used in image reader, software and IP realizes images of the finest quality possible expected in digital imaging.
Excellent accuracy is the FCR standard with our automatic contrast optimization for each image and wide dynamic range which incorporates the trusted FCR technology.
Information in the IPs can be read with no need of using a hard cassette.
Various IP shapes are available thanks to special tools developed to read special size and shape IPs making it possible to inspect objects of any shape with high accuracy.
The pipe wall thickness is automatically measured based on Fujifilm's precise image analysis technology to make an inspection more efficient and stable.
Automatically adjusts contrast and density of an image to allow defect comparison between production images and ASTM Digital Reference Radiographs.
Reads up to 152 cm long IPs allowing efficient inspection of larger objects.
The user can customize and preset the automatic density adjustment parameter (Exposure Data Recognizer: EDR) suitable for the test object. Easy density adjustment is possible with just one-click.
Presets of frequently used search conditions can be created enabling one-click data retrieval.
Assessment of images is automated to reduce human labor and errors. The assessment history is recorded to enhance traceability.
Processes from image reading to inspection can be conducted on one PC with smooth transition between image reading and inspection windows.
The entire test process is managed on one main screen. The data tree structure and work status are shown at a glance.
Features assisting inspectors such as larger icons with customizable tool bars, masking and viewer friendly displays make inspection easier.
Centralized management of inspection data at multiple sites on a centralized server accessible via Intranet or Major ERP Applications.
User access rights to individual functions can be controlled. With user rights management, user functions are limited by authority and workspace is increased by the removal of unauthorized tools.
High resolution reading at a 25 μm pitch, unique image processing and highly capable IP ― fusion of the best of Fujifilm's technologies realizes images of the finest quality possible expected in digital imaging.
Since the introduction of the world's first digital diagnostic X-ray imaging system FCR in 1983, Fujifilm has developed imaging processing technologies suitable for objects which have undergone NDT. For DynamIx VU, we have adopted Exposure Data Recognizer (EDR) to automatically adjust the density and our proprietary image processing technology Fuji Image Processing (FIP). With these technologies, it is possible to provide optimized images of any test object. Moreover, users can customize parameter presets for image processing. Anyone can easily perform image adjustment suitable for the test object.
DynamIx inherits the FCR technology of Fujifilm which has been on the frontier of film and digital image resolution technologies. With the wide dynamic range of four or more orders of magnitude, every part of an object—either thick part or thin part—is clearly expressed, free from blown out highlights, blocked up shadows or unevenness.
Different from conventional measurement based on the human eye, Fujifilm's precise image analysis technology automatically detects the inner and outer edges of pipe wall and measures the wall thickness.** Easy but accurate corrosion tests are performed reducing the need for difficult manual measurements.
Efficient examination of welded pipe joints can be conducted in a small number of exposures. Reading of images on IPs of up to 152 cm long reduces the number of exposures needed for large jobs.
The image reader receives an IP and ejects it from the front. This unique design makes it possible to read IPs of up to 152 cm long in a narrow space. A sequence of operations can be carried out in the same place with just a few actions.
DynamIx Special Cut IP System provides an IP optimally shaped for an inspection object. To utilize IPs of various shapes, special tools have been developed dramatically reducing limitations. Now a variety of objects can be inspected at high accuracy.
DynamIx VU Contrast Normalization* automatically adjusts the contrast of the reference image*5 specified by ASTM to conform to the one of the target image.
The software enables reading and inspection to be conducted on a computer, with quick switching between the screens. Access to the image database is also smooth, so that an image appears on the inspection screen instantly after it is read. This feature enhances the work efficiency in each process.
The user can customize and preset the automatic density adjustment parameter (Exposure Data Recognizer: EDR) suitable for the test object. Easy density adjustment is possible with just one-click.
Frequently-used search conditions can be preset, enabling one-click data retrieval with no need to input search conditions every time.
DynamIx VU newly offers DynamIx VU Judge* the automatic image quality assessment. This program calculates the image quality index based on the measured normalized signal-to-noise ratio (NSNR) of an image, and assesses if the index conforms to a standard image quality assessment index. This saves the need of measurement and calculation by humans.
In addition to ISO standards, industry-specific standards are supported as the assessment criteria. The screen to input defect determination results is offered. The results can be recorded on the system.
Each assessment is recorded according to who, when and what, contributing to the enhanced traceability.
With DynamIx VU Report*, reports in the specified formats are prepared automatically at the end of an NDT only by inputting test data such as the exposure conditions, results of image quality assessment and of defect determination on the relevant screens. As a report is created in Microsoft® Word®, it is readily used on other Microsoft® software. The report format or the file format is customizable.
The DynamIx system is customizable according to the existing network environment. By managing the inspection image data at multiple sites on a central server, an inspector can access the data anywhere via the network to assess the image. Linked with Intranet or Major ERP Applications, it is possible to send a test request made on an ERP package to each test site, or receive a test report vice versa. Thus, an efficient workflow improving the NDT process is established.
A user's access right to each function can be assigned by the administrator to limit viewing or editing of data to the minimum necessary and strengthen the security. With this function enabled, the system shows only the functions pertinent to the user, offering simple and easy-to-use screen interface.
| IP Image Reader | DynamIx HR2 |
|---|---|
| Reading density | 25 μm, 50 μm, 100 μm, 200 μm |
| Reading gray scale | 14 bits / pixel |
| Dimensions (W × D × H) | 600 × 660 × 490 mm (24 × 26 × 19 in.) |
| Weight | 58 kg (127 lb.) |
| Power supply | 100-240 V AC, 50/60Hz, 400 VA or less |
| Operation condition | 15°C-30°C, 15%-80%RH (No dew condensation) |
| IP Tray | Hand-held type |
| Tools for using special cut IPs | Type S : Custom order Type F : Custom order |
| Fixed-size IP | ST-VI (Type CC Cassette) | 35.4 × 43.0 cm (14.0 × 17.0 in.) 18.0 × 24.0 cm (7.1 × 9.4 in.) 24.0 × 30.0 cm (9.4 × 11.8 in.) 15.0 × 30.0 cm (5.9 × 11.8 in.) |
|---|---|---|
| UR-1 (Type UR Cassette) | 35.4 × 43.0 cm (14.0 × 17.0 in.) 18.0 × 24.0 cm (7.1 × 9.4 in.) |
|
| Strip-form IP | 6.0 × 40.0 cm (2.4 × 15.7 in.) Note : Consult with our sales representative for other sizes. |
|
| Long IP | 7.0 × 152.0 cm (2.8 × 59.8 in.) Note : Consult with our sales representative for other sizes. |
|
| Software | DynamIx VU Console Acquires images from the image reader and adjusts image quality. |
|---|---|
| DynamIx VU Viewer Enables assessment of image quality and determination of defects by using various measurement tools. |
|
| DynamIx VU Server Stores data and enables data management. |
|
| Client PC | CPU : Intel® Core™ i7 CPU at 2.6 GHz or greater |
| OS : Windows® 7 Professional 64 bit Service Pack 1 English | |
| Server PC | CPU : Intel® Xeon® E3-1225 at 3.10 GHz or greater |
| OS : Windows® Server 2008 R2 Service Pack 1 English | |
| Display | Standard viewer : 21.2 inch 3M high resolution color LCD monitor Recommended model : EIZO® Radiforce RX340 Resolution : 1536 × 2048 pixels |
| high grade viewer : 21.3 inch 5M high resolution monochrome LCD monitor Recommended model : EIZO® Radiforce GX530 Resolution : 2048 × 2560 pixels |
![[Image] Dimensions](img/index/pic_spec_01.jpg)