Prescale : Specifications

Prescale

Specifications and Operational Environment

Accuracy

±10% or less (measured by densitometer at 23°C,65% RH)

Recommended service temperature

20°C∼35°C( 68 °F∼ 95°F )(*1)

Recommended service humidity

35% RH ∼ 80% RH(*2)

Thickness

mono-sheet type(S): 100µm
two-sheet type(W):100µm x2

  • *1 Extreme low pressure (4LW), Super high pressure (HHS): 15 °C∼30°C
  • *2 Extreme low pressure (4LW): 20% RH ∼ 75% RH
        Super high pressure (HHS): 35% RH ∼ 70% RH


Pressure Chart (Low Pressure <LW> case)

Continuous pressure

Measurement pressure range:Low pressure (2.5∼10 MPa)
Pressure application condition:Time to reach the pressure 2 min.
Time of retention at the pressure 2 min.

  • * Taking the temperature and humidity condition into consideration, select a curve among A, B and C.

Momentary pressure

Measurement pressure range:Low pressure (2.5∼10 MPa)
Pressure application condition:Time to reach the pressure 5 sec.
Time of retention at the pressure 5 sec.

  • * Taking the temperature and humidity condition into consideration, select a curve among A, B and C.