In order to provide you with a better browsing experience and to improve our site functionality, we use cookies and other tracking technologies. Detailed information on the use of cookies on our site and how to opt out is provided in our Cookie Policy. By clicking into any content on this site, you consent that we can store and access cookies and other tracking technologies as described in our Cookie Policy.

Indonesia
[photo] DRI-CHEM IMMUNO AG2 rapid diagnostic system

DRI-CHEM IMMUNO AG2

NEW

An advanced rapid diagnostic system for infection with high sensitivity and high specificity technology.

The content on this page is intended to healthcare professionals and equivalents.

Auto-determination without using a timer offers a speedy and effective test for infection.

The IMMUNO AG2’ s highly sensitive detection technology using silver amplification principle of photographic development offers accurate detection of a small amount of antigen during early stages of flu.
 
Easy operation allows the user to set a sample and execute automatic determination, reducing the labour for inspection, and prevents determination errors that are common with the visual inspection method.
 
The barcode reader offers the convenience to users. 
 
The IMMUNO AG2 brings efficiency to test for infection reducing the burden to patients through early detection.

Dedicated Reagent for FUJI DRI-CHEM IMMUNO AG

Influenza type A and B virus antigen
[photo] FUJI AG test cartridge for Influenza type A and B virus antigen with light blue label

Influenza virus kit

Sample typeNasopharyngeal swab
Reaction time3.5 to 15 minutes

 

RS virus antigen Adenovirus antigen
[photo] FUJI AG test cartridge for RS virus and Adenovirus antigen with light green label

RS virus and Adenovirus kit

Sample typeNasopharyngeal swab
Reaction time3.5 to 15 minutes

 

High sensitivity detection technology

High specificity technology

No need to measure time / The shortest detection time, 3.5 min.

After dropping the sample liquid onto the reagent cartridge and inserting it into the port, the system automatically starts the measurement. Further manual operation is not required until the measuring result is printed out. For FluAB, the shortest measurement time is about 3.5 minutes. If the system cannot make a determination, it automatically starts a sensitization test.

[image] Gloved hands writing name and dropping sample liquid onto AG Flu Test cartridge, then inserting into equipment and receiving automatically printed test results paper
[On measuring FluAB]
[image] Steps for measuring FluAB with AG Test in 15 minutes, from start of measurement, start of determination, determination, start of sensitizing, and judgement

Accurate reading of results

The system automatically reads the results. Thus human error in reading result can be avoided unlike the visual inspection method.

Positive (*: Not determined)
Negative
Positive

Simple design to improve usability

Intuitive touch panel
[photo] Gloved hand pressing touch panel on DRI-CHEM IMMUNO AG2 system display
Easy to disinfect design
[photo] DRI-CHEM IMMUNO AG2 front and side views
Suitable for multiple installation
[image] 3 DRI-CHEM IMMUNO AG2 systems next to each other in a row, with width, depth, and heigh dimension highlighted