This website uses cookies. By using the site you are agreeing to our Privacy Policy.



7000 System

Endoscope system with diagnosis and usability contains the light source which features high-intensity 4 LED lights.

Caution

  • * This is Fujifilm Global Website. Fujifilm makes no representation that products on this website are commercially available in all countries.
  • * Approved uses of products vary by country and region.
  • * Specifications and appearance of products are subject to change without notice.

7000 System provides you with the following product lineup.

Processor

  • VP-7000

Light source

  • BL-7000

Video Endoscope

Upper G.I. tract scopes

  • EG-760R
  • EG-760Z

Lower G.I. tract scopes

  • EC-760R-V/M, I, L
  • EC-760ZP-V/M, L

Processor

VP-7000

[Image]VP-7000
Power 100 to 240 V ± 10 %, 50/60 Hz
Power consumption (rated) 0.8-0.5 A
Dimensions (W×H×D) 390×110×485 mm (incl.projection)
Weight 9.0 Kg
Observation Type of color NTSC/PAL
Digital HDTV HD-SDI: 2, DVI-D: 2 
Analog/Digital HDTV DVI-I: 1
Analog SDTV RGB TV: 1, S VIDEO: 1, VIDEO: 1
Screen resolution SXGA (Default), Full HD
Color adjustment Brightness, Red, Green, Blue, Red tone, Chroma in nine levels (-4 to +4). Contrast in five levels (-1 to +4).
Contrast Available in three levels (-1 to +1).
Iris mode Function to control the screen brightness.
AVE (controls brightness in general), PEAK (controls brightness in highlight areas), AUTO (sets average or peak iris automatically)
Structure emphasis Function to adjust the sharpness of the subject structure. SE (Structure Emphasis) 4 level, DH (fine section) -4~+9, DL (structure section) -4~+9.
Tone Function to emphasize slight differences between colors by emphasizing the degree of vividness of color. ON/OFF.
Enlargement of the image Function to enlarge the endoscopic image.
Special light observation mode BLI, BLI-bright, LCI
FICE Ten settings available.
Mask types Type 1, Type 2, Type 2/Dual Mode.
Freeze mode Function to freeze the endoscopic images.
Peak detection Function to obtain the highest contrast image.
Shutter speed Normal 1/60-1/200, High 1/100-1/400, High (zoom scope) 1/100-1/800
Assignment of switches Scope Switch (1-5), Multi buttons on the front panel (1.2), Foot Switch (1,2).*1
Other functions Electronic Zoom, PoP Function, Network function, Dual Mode function.
Applicable endoscope 700 system scopes, 600 system scopes, 500 system scopes
Data display Remote control Fujifilm specified peripherals can be controled.
Patient information Patient ID, Patient Name, Sex, Age, Date of Birth, Comments, Hospital name, Doctor name *2
Other information Timer, Laptime
Recording status Digital printer status, shooting counter, number of recordable images in internal storage device
Image quality setting status Structure emphasis, Tone, Electronic Zoom Ratio, IEE observation modes, Focus Indicator.
Image recording Image compression rate TIFF: no compression, JPEG: approx. 1/5 , 1/10, 1/20 
Number of recordable images in internal storage device TIFF: 840, JPEG 1/20: 21,690, JPEG 1/10: 16,270, JPEG 1/5: 5,910 *3
Recommended external storage device Swissbit SFU-22048 E1BP2TO-I-MS-111-STD or SFU22048E3BP2TO-I-MS-121-STD *4
Searching and displaying images Search screen: Inspection No., Patient ID, Date of Inspection. Display: List, Thumbnail, Enlargement.
Data presetting Doctors' name Up to 20 doctors’ names.
Setting by doctor The information such as color tone, iris mode, contrast, brightness, IEE observation modes are kept by setting the doctor's name.
Clinical procedure Up to 20 procedures.
Memory backup When using lithium battery 6 years (based on FUJIFILM criteria)
Control connector Light source: 1, Remote: 2, Peripherals: 2, Keyboard: 1, Card reader: 1, Digital printer: 1, Footswitch: 1, Network: 1.
Category of medical electric equipment Type of protection against electric shock Class I equipment
Degree of protection against electric shock Type BF applied part
Degree of explosion protection Prohibited in oxygen-rich environment/ flammable gas atmosphere.
  • *1 Some limitations by endoscopes.
  • *2 Max. 45 patients
  • *3 The number of recordable images varies depending on the type of image.
  • *4 Concerning other external storage devices, please contact your representative or local dealer.
  • Product : Processor
  • GMDN: 18034
  • Generic name: Endoscopic Video image processor

Light source

BL-7000

[Image]BL-7000
Power 100 to 240 V~ ± 10 %, 50/60 Hz
Power consumption (rated) 1.2-0.7 A
Dimensions (W×H×D) 390×155×485 mm (incl.projection)
Weight 12Kg
Illumination Illumination source LED, qualifies 300W Xenon lamp intensity
Durability of LED 6 years (based on FUJIFILM criteria)
Lighting system Switching regulator
Light control method LED Auto power control
Light cooling method Forced air cooling
Special light observation mode BLI, BLI-bright, LCI
Maximum light output 1400 lm (based on FUJIFILM criteria)
Maximum air supply pressure 65 kPa
Automatic brightness adjustment Automatic brightness adjustment method Brightness is automatically adjusted according to the video output (manually possible).
Air supply Pump Diaphragm method pump
Air supply pump HI/MID/LOW/OFF
Water supply Method Feeds water by pressurizing the detachable water container with air.
Indicators on front panel Transmitted illumination The light flashes with the maximum light intensity. Used to check the position of the distal end from outside the body.
Light limitation To avoid the blood of a bleeding patient becoming clotted by the illuminating light. Used to limit the maximum light intensity.
Illumination mode OFF/1/2/3. Observation modes can be switched by pressing the illumination mode button.
Memory of set value Set values are maintained even after turning off the system.
Category of medical electric equipment Type of protection against electric shock Class I equipment
Degree of protection against electric shock Type BF applied part
Degree of explosion protection Prohibited in oxygen-rich environment/ flammable gas atmosphere.
  • Product : Light source
  • GMDN: 35158
  • Generic name: Endoscopic light source, line-powered

Video Endoscope

Upper G.I. tract scopes
EG-760R

[Image]EG-760R
Viewing direction 0° (Forward)
Field of view 140°
Observation range 2-100 mm
Image size Super image
Distal end diameter 9.2 mm
Insertion tube diameter 9.3 mm
Minimum diameter of instrument channel 2.8 mm
Bending capability UP 210° / DOWN 90°
RIGHT 100° / LEFT 100°
Working length 1,100 mm
Total length 1,400 mm
  • Product : Video Endoscope
  • GMDN: 38805
  • Generic name: Flexible video gastroduodenoscope
[Image]EG-760R

Video Endoscope

Upper G.I. tract scopes
EG-760Z

[Image]EG-760Z
Viewing direction 0° (Forward)
Field of view Normal: 140° Closest: 56°
Observation range 1.5-100 mm
Normal: 3-100 mm
Closest: 1.5-2.5 mm
Image size Super image
Distal end diameter 9.9 mm
Insertion tube diameter 9.8 mm
Minimum diameter of instrument channel 2.8 mm
Bending capability UP 210° / DOWN 90°
RIGHT 100° / LEFT 100°
Working length 1,100 mm
Total length 1,400 mm
  • Product : Video Endoscope
  • GMDN: 38805
  • Generic name: Flexible video gastroduodenoscope
[Image]EG-760Z

Video Endoscope

Lower G.I. tract scopes
EC-760R-V/M, I, L

[Image]EC-760R-V/M, I, L
Viewing direction 0° (Forward)
Field of view 170°
Observation range 2-100 mm
Image size Super image
Distal end diameter 12.0 mm
Insertion tube diameter 12.0 mm
Flexibility Adjustment Mechanism Available
Minimum diameter of instrument channel 3.8 mm
Bending capability UP 180° / DOWN 180°
RIGHT 160° / LEFT 160°
Working length 1,330 mm(M)/1,520 mm(I)/ 1,690 mm(L)
Total length 1,650 mm(M)/1,840 mm(I)/ 2,010 mm(L)
  • Product : Video Endoscope
  • GMDN: 36117
  • Generic name: Flexible video colonoscope, reusable
[Image]EC-760R-V/M, I, L

Video Endoscope

Lower G.I. tract scopes
EC-760ZP-V/M, L

[Image]EC-760ZP-V/M, L
Viewing direction 0° (Forward)
Field of view Normal: 140° Closest: 56°
Observation range 1.5-100 mm
Normal: 3-100 mm
Closest: 1.5-2.5 mm
Image size Super image
Distal end diameter 11.7 mm
Insertion tube diameter 11.8 mm
Flexibility Adjustment Mechanism Available
Minimum diameter of instrument channel 3.2 mm
Bending capability UP 180° / DOWN 180°
RIGHT 160° / LEFT 160°
Working length 1,330 mm(M)/1,690 mm(L)
Total length 1,650 mm(M)/2,010 mm(L)
  • Product : Video Endoscope
  • GMDN: 36117
  • Generic name: Flexible video colonoscope, reusable
[Image]EC-760ZP-V/M, L

Notes:

  • Specifications and appearance of products are subject to change without notice.
  • Language of indications on products varies by country and region.
  • Products comply with regulations of the country or region where they are marketed.