DRI-CHEM from FUJIFILM is a dry chemistry analyzer which can perform multiple test parameters of Clinical Chemistry.
It has a built-in auto-pipetting system, requires no calibration*1 and no water, providing easy preparation and maintenance. The new DRI-CHEM NX500 delivers results using a simple 3-step procedure. With its quick, easy operation and compactness,
“Real Time and Borderless” Clinical Chemistry is made possible.
*1 Except for CRP
Fully Automated Procedure
1. Set the slide (Dry Slide Reagents). 2. Set the sample. 3. Press START.
No Parameter Input Required
Information of the parameter is incorporated in the bar code printed on the back of every slide.
![[image] Machine function: Dry slide reagents identified and samples applied, placed inside incubator, results measured/displayed, and slide placed in disposal](https://asset.fujifilm.com/www/th/files/2020-04/0eeeb1c514fb80506a321198d0029232/fig_dri-chem-nx500_02.jpg)
5.7 inch VGA, 640 5 480. Qwerty touch Key board. Basic Mode / Advanced Mode are available according to user preference.
(Basic Mode: displays operation procedure for one sample only. Advanced Mode: displays operation procedure for one sample and measurement status for previous measured samples.)
Plasma Filter (PF) can cut the turn around time and the pre-treatment process of the sample. It can generate plasma sample by aspirating and separating the whole blood inside the PF within 1 minute. Just set the PF on top of the sample tube and press START.
![[image] Result list view with list of test results on screen, labeled by patient name and other modes: Help mode, Basic mode/Advanced mode](https://asset.fujifilm.com/www/th/files/2020-04/95034b28e90e0a5e9487b84bd330cebc/fig_dri-chem-nx500_03.jpg)
![[image] Illustration of sample tube of red blood with yellow plasma separating from blood and accumulating at the top of tube](https://asset.fujifilm.com/www/th/files/2020-04/6fccc81f117030e56ca42ec2f42649b2/fig_dri-chem-nx500_04.jpg)
- * PF function is available in NX500 only.
- * TCO2: not applicable
Each test needs only 10μL of sample.
(CRP needs 5μL/test, ISE needs 50μL/3 tests). Manual pipetting can be also performed when less sample available. Less invasive for newborn at NICU.
Dilution, a time consuming process, is also automated in FUJI DRI-CHEM. Just set the ratio of dilution and press START. Dilution test also can be performed simultaneously with the regular tests, requiring no separation of tests.
A magnetic card called QC card will adjust the lot variability in the slide reagents.
A QC card comes with every reagent box. The analyzer memorizes the lot adjustment information once a QC card is swiped. No need to swipe QC in every measurement for the same slide lot.
- *2 CRP: Further calibration by liquid calibrators is needed.
- ISE: QC card system is not used.
The NX500 analyzer can provide results for 6 calculated parameters. No need for external calculation for commonly used parameters.
Slide reagents after measurement will be automatically discarded to the disposal box, minimizing the risk of contamination.
Blood Collection Tube (φ13~16 × 75~100mm)
FUJI PLAIN TUBE (0.5mL, 1.5mL)
FUJI HEPARIN TUBE (0.5mL, 1.5mL)
USM (User Safety Mode) function is now introduced to
NX500 as a selectable function.
Main features
- User ID registration system; Non-registered person cannot operate NX500. For this application, Operator ID Editor Kit (option item) is necessary to register and edit operator ID on your PC.
- No result reporting from expired colorimetric slides.
- Expanded data transmission; Operator ID, Slide information (Lot/expiry) and Analyzer ID
The FUJI DRI-CHEM slide reagent has high reliability and stability brought by fine chemical technology cultivated through the long history of FUJIFILM in photographic film manufacturing.
Less variation of results between operators, high result reproducibility and daily precision,
and excellent correlation with wet chemistry are its remarkable features.
![[image] GOT/AST chart with results of using FUJI DRI-CHEM slide reagent with IFCC standardization method](https://asset.fujifilm.com/www/th/files/2020-04/64528b0cb93f8581e5bdacdae9816254/fig_dri-chem-nx500_06.jpg)
IFCC standardization method (no PALP) (U/L)
![[image] GLU chart with results of using FUJI DRI-CHEM slide reagent with Hexokinase method](https://asset.fujifilm.com/www/th/files/2020-04/79dc27d336b13454244323d7688b0129/fig_dri-chem-nx500_07.jpg)
Hexokinase method (mg/dL)
![[image] K chart with results of using FUJI DRI-CHEM slide reagent with Emission flame method](https://asset.fujifilm.com/www/th/files/2020-04/be2a7734105b52f00bcb28345c111ada/fig_dri-chem-nx500_08.jpg)
Emission flame method (mEq/L)
![[image] CRE chart with results of using FUJI DRI-CHEM slide reagent with Enzymatic method](https://asset.fujifilm.com/www/th/files/2020-04/bd367ff24ecb5935f3642da7bca88ad5/fig_dri-chem-nx500_09.jpg)
Enzymatic method (mg/dL)
(Enzymes, General chemistry, and Immunology)
This multilayered slide is composed of dry chemical ingredients needed for the reaction and other functional materials. It quantifies enzymes and chemicals using colorimetric method.
![[image] DRI-CHEM Slide composition of multilayered film - Spreading layer, Reflection layer, Reaction layer, Transparent support film, and Spectrophotometer](https://asset.fujifilm.com/www/th/files/2020-04/478f8cccf29f6003bcf788ed32a5a10c/fig_dri-chem-nx500_10.jpg)
(Electrolytes)
Each slide comes with an ion selective film electrode for each of Na, K, and Cl. Slides quantify electrolytes in the sample by a potentiometric method.
![[image] Potentiometric method electrolytes slide - electrode terminal, potentiometer, pertition materials, and multilayered film electrode](https://asset.fujifilm.com/www/th/files/2020-04/3cb518f8f0ad2d3e42ff90d053af4050/fig_dri-chem-nx500_11.jpg)