The content on this page is intended to healthcare professionals and equivalents.
![[photo] ED-580T / ED-580XT](https://asset.fujifilm.com/www/ar/files/2024-07/4db570c9f9149d092383ab32187fdff9/pic_duodenoscopes_01.jpg)
![[photo] Close-up view of the distill end cap on the ED-580T / ED-580XT](https://asset.fujifilm.com/www/ar/files/2024-07/13e9e5fe0f85bc6b522bd7e51c688865/pic_duodenoscopes_02.jpg)
- Viewing direction
ED-580T
105° (retro-viewing 15°)ED-580XT
95° (retro-viewing 5°)- Field of view
100°
- Observation range
4-60mm
- Bending capability
UP 120° / Down 90° / Left 90° / Right 110°
- Working length
1250mm
- Total length
1550mm
- Distal end diameter
13.1mm
- Insertion tube diameter
11.3mm
- Minimum diameter of instrument channel
4.2mm
- Product name:Video Endoscope
- GMDN:36112
- Generic name:Flexible video duodenoscope, reusable
![[image] Graphical rendering of the aeriel view of the ED-580T / ED-580XT with labels point to the Air/Water Nozzle, Instrument Channel Outlet, Objective lens, Light Guide, Forceps Elevator,](https://asset.fujifilm.com/www/ar/files/2024-07/c0e3ca7a5b25d77346bbd574848a597f/fig_duodenoscopes_01.jpg)
![[image] Graphical rendering of Bending Capability up 120 degrees](https://asset.fujifilm.com/www/ar/files/2024-07/fe0c37479262f18a4b7d3f206e104b6b/fig_duodenoscopes_02.jpg)
![[image] Image area & forceps entry position](https://asset.fujifilm.com/www/ar/files/2024-07/aaa67a6616a59471c035eeec73119daa/fig_duodenoscopes_03.jpg)
![[photo] SB-605 Suction Valve](https://asset.fujifilm.com/www/ar/files/styles/600x400/public/2024-07/28d1c1f7076e4fc08b7a2d2e7187c557/pic_duodenoscopes_03.jpg?itok=HHL3RwGx)
Suction Valve
![[photo] AW-603 Air/Water Valve](https://asset.fujifilm.com/www/ar/files/styles/600x400/public/2024-07/b72b8005c4b426d832dbc605d0b5bc60/pic_duodenoscopes_04.jpg?itok=wLPVx8jg)
Air/Water Valve
![[photo] AW-604G Gas/Water Valve](https://asset.fujifilm.com/www/ar/files/styles/600x400/public/2024-07/60a39c8bed0835c95fe760414411b6d1/pic_duodenoscopes_05.jpg?itok=W6V7KqmE)
Gas/Water Valve
![[photo] DC-07D](https://asset.fujifilm.com/www/ar/files/styles/600x400/public/2024-07/a66d70f331fba2b384e1e6f228a9e096/pic_duodenoscopes_06.jpg?itok=dSk_0pw9)
![[photo] WB11003DV for suction valve cylinder, air/water valve cylinder and instrument channel inlet](https://asset.fujifilm.com/www/ar/files/styles/600x400/public/2024-07/d62a008d57c663e0f4005ccde9017fa4/pic_duodenoscopes_07.jpg?itok=VP47fX_s)
for suction valve cylinder, air/water valve cylinder and instrument channel inlet
![[photo] WB7025DC for instrument channel and suction channel](https://asset.fujifilm.com/www/ar/files/styles/600x400/public/2024-07/ec73de37adc03cf389b9ff6841c656db/pic_duodenoscopes_08.jpg?itok=o5XM5Jz0)
for instrument channel and suction channel
![[photo] WB1318DE for distal end and forceps elevator](https://asset.fujifilm.com/www/ar/files/styles/600x400/public/2024-07/36fa892b0b68f91622ab0ff8fc2818c9/pic_duodenoscopes_09.jpg?itok=bpmkwysd)
for distal end and forceps elevator
![[photo] Side by side close-up views of Covering the distil end cap and attaching it tightly](https://asset.fujifilm.com/www/ar/files/2024-07/1e543fff7c44c61d7c26169806f96938/pic_duodenoscopes_10.jpg)
![[photo] Side by side close-up views of how to detach the distal cap by turning a portion near the instrument channel and turning the counter-clockwise to pull it straight out](https://asset.fujifilm.com/www/ar/files/2024-07/52e88b37e41a4d468e711105c1fd61de/pic_duodenoscopes_11.jpg)