In order to provide you with a better browsing experience and to improve our site functionality, we use cookies and other tracking technologies. Detailed information on the use of cookies on our site and how to opt out is provided in our Cookie Policy. By clicking into any content on this site, you consent that we can store and access cookies and other tracking technologies as described in our Cookie Policy.

Singapore
Home Healthcare X-ray Imaging Devices Digital X-ray Radiographic - Fluoroscopic Table System CUREVISTA Apex CUREVISTA Apex : Low Dose

Premium Digital RF System

CUREVISTA Apex - Low Dose

Assists physicians. Crystal clear imaging. Dose highlight. The flagship model for EndoTherapy.

The content on this page is intended to healthcare professionals and equivalents.

Low dose.
Now visualized.

Occupational exposure. Keep it lower. And the minimal.
Now, it is time to visualize invisible rays.

Take a look at the "invisible".

IntelliMAP 
Exposure Dose Map*1

Dose ... it is a concern for every healthcare professional. Now, CUREVISTA  Apex visualizes it for you. Simulates scattered X-rays from the actual irradiation dose and maps the dose distribution. Let's consider measures to reduce occupational exposure. Let's change everyone's awareness of radiation exposure. This is our "intuitive visualization proposal" for further dose reduction.

Half dose.
Same image quality.

IntelliFRAME 
Frame Conversion*1

Reduce the dose to half without sacrificing smoothness. Typically, the more pulse you shoot, the smoother the fluoroscopy becomes. IntelliFRAME will blow your mind. Set the pulse rate to 1/2 and activate IntelliFRAME. The dose becomes 50%, yet smoothness maintains by frame interpolation. EndoTherapy.
Pediatrics. OB/GYN. Half dose with no image degradation.

Trim it. Independently.

IntelliSHUTTER 
Independent Collimator Shutter*1

There's no need to move the patient . Shape the beam as you wish (rectangle). Upper. Lower. Left. Right. The four shutters slide independently, making procedures easier without moving the patient. Left from the spine. Upper half only. Only one lung field. Zoom the remaining area into the center of the display.

As many as you want
with no added dose.

IntelliSHOT 
Fluoro. Screenshot

Dose-free screenshot.
Because VISTABRAIN's fluoroscopy is resistant to motion, you can capture a frame at the right moment.
There are no additional shots to increase the radiation dose. With CUREVISTA Apex, let's take screenshots (sent in DICOM format) instead of additional exposures.

Dose notification.
Be seen. Be heard.

IntelliALARM 
Cumulative Dose Notification

CUREVISTA Apex will let you know the accumulated radiation dose. When the irradiation dose exceeds the value that you registered with IntelliALARM, the system notifies the fluoro room and control room with a message and sound.

  • *1 Option