This website stores cookies on your computer. These cookies are used to collect information about how you interact with our website and allow us to remember you. We use this information in order to improve and customise your browsing experience and for analytics and metrics about our visitors both on this website and other media. By continuing to use our website, you accept the use of all cookies on our website. To find out more about the cookies we use and how to opt-out of the use of cookies, see our Privacy Policy.

Australia

ARIETTA 50LE - Instruction Video

Compact model equipped with a monitor arm for easy operation by both beginners and expert.

The content on this page is intended to healthcare professionals and equivalents.

  • These videos are filmed with the system for the Japanese market. The actual appearance of the system may differ.
  • Screen displays and specifications may differ depending on the version of the system.
Preparing for examination            

1. Operation panel (0:05~)
2. Transducer connection(0:18~)
3. Power On/Off(0:37~)

Basic operation (B mode)

1. Input of patient information / Transducer and application changing(0:05~)

  • From the Home screen
  • With the [New Patient] key, input of patient information
  • From the [Probe] key, transducer and application changing

2. Gain adjustment(1:42~)

  • B mode gain adjustment
  • Gain adjustment by depths
  • Automatic gain adjustment

3. Dual display(2:43~)
4. Display range adjustment(3:10~)
5. Focus position adjustment(3:28~)
6. Zoom(3:56~)

  • Box zoom
  • Center zoom

7. Freeze(5:10~)
8. Cine Search(5:30~)
9. Body Mark(5:53~)
10. Entering comments(6:17~)

  • Entering texts
  • Entering a pointer
  • Deleting comments

11. Saving images(7:39~)

  • Saving still images
  • Saving videos
Operation of Color Doppler mode, D mode and M mode

1. Color Doppler mode(0:05~)

  • Color Flow mode
  • Power Doppler mode
  • eFLOW mode
  • Color Doppler gain adjustment
  • Flow Area settings
  • Flow area angle adjustment
  • Dual display of B mode and Color Doppler mode

2. D mode(2:01~)

  • Doppler waveform display
  • Sample volume adjustment
  • Angle correction <manual>
  • Angle correction <auto>
  • Velocity range adjustment
  • Baseline adjustment
  • Automatic adjustment of velocity range and baseline
  • D gain adjustment
  • Sweep speed adjustment

3. M mode(4:15~)

  • M mode display
  • M mode gain adjustment
  • Sweep speed adjustment
Measurement and other operations

1. Measurement(0:05~)

  • Distance Measurement
  • Deleting measurement results
  • IMT automatic measurement 
  • Blood flow velocity measurement <manual>
  • Blood flow velocity measurement <auto>

2. Other operations(2:05~)

  • Trapezoidal display of linear transducer
  • Puncture guide line display
  • Needle Emphasis
  • Arbitrary M mode display (FAM: Free Angular M mode)
  • Side-by-side display with slow-motion image (DSD: Dynamic Slow-motion Display)
  • History
  • Viewing Instruction Manuals
Review

1. Review(0:05~)

  • Searching for an image
  • Image playback

2. Delete/Output(1:25~)

  • Deleting images
  • Image output in PC format
  • Image output in DICOM format