Uzbekistan

ARIETTATM 750VE

Supporting efficient and high-quality examinations including general routine checks and follow-ups.

The content on this page is intended to healthcare professionals and equivalents.

Diagnostic ultrasound system is used in a wide range of situations from screening and outpatient diagnosis to follow-ups. The ARIETTA 750VE meets a wide range of clinical needs of clinical sites with easy-to-use applications as well as high image quality, which is essential for presence diagnosis and qualitative diagnosis.

SEAMLESS WORKFLOW

Protocol Assistant

Prior fixed examination protocols and imaging conditions can be registered. Button operations can be reduced significantly to support efficient examinations. Additionally, a reference image can be displayed via the "Guide View" function.

Advanced Workflow for Real-time Tissue Elastography(RTE)

HI Strain

HI Strain is an algorithm used to display an Elastography image more consistently than before. It is possible to display Elastography images with high continuity while maintaining temporal resolution and spatial resolution.

YOUR APPLICATION

[Examination] Elastography

Real-time Tissue Elastography (RTE)

RTE assesses tissue strain in real time and displays the tissue stiffness as a color map. Its application has been validated in a wide variety of clinical fields, and it is possible to calculate an estimate value of liver fibrosis staging.

Shear Wave Measurement (SWM)

It is possible to evaluate tissue stiffness  by generating shear waves and measuring Vs, its propagation velocity in the tissue. Combi-Elasto, which integrated RTE and SWM, is expected to be used for cases which are difficult to diagnose through only using SWM.

ATT measurement

A function to measure the attenuation coefficient generated in the process of ultrasound propagation of tissue. The degree of steatosis can be estimated from the size of the coefficient. Its measurement is conducted simultaneously with SWM, and it can be conducted as an extension of B mode examination.

Contrast Harmonic Imaging (CHI)

Contrast enhanced ultrasound is used widely for clinical practices such as tumor detection, differential diagnosis, and treatment support. High definition and high sensitivity contrast imaging is realized by Variable Beamformer and high sensitivity transducers. 

Detective Flow Imaging (DFI)

Imaging technology for visualization of low velocity blood flow below the previous detection threshold. A unique algorithm displays fine blood flow with greater resolution and sensitivity.

[Treatment] Real-time Virtual Sonography(RVS)

MPR images constructed from CT/MRI/PET-CT volume data can be synchronized to real-time ultrasound imaging. It is applied in a wide variety of clinical fields: such as for Abdomen, Breast, navigation in prostate puncture, and so on.