In order to provide you with a better browsing experience and to improve our site functionality, we use cookies and other tracking technologies. Detailed information on the use of cookies on our site and how to opt out is provided in our Cookie Policy. By clicking into any content on this site, you consent that we can store and access cookies and other tracking technologies as described in our Cookie Policy.

Vietnam

DRI-CHEM NX500

NEW

A multi-purpose automatic dry-chemistry analyzer featuring remarkably short turnaround time, a touch screen interface and reliability.

The content on this page is intended to healthcare professionals and equivalents.

Parameters

Classification Parameter Measurement range *1 Measurement time
(min.)
Unit (A) Unit (B)
Biochemical tests Enzymes ALP 14 – 1183 U/L 0.23 – 19.76 μ Kat/L 4
AMYL 10 – 1800 U/L 0.17 – 30.06 μ Kat/L 5
CHE 5 – 500 U/L 0.08 – 8.35 μ Kat/L 4.5
CKMB 1 – 300 U/L 0.02 – 5.01 μ Kat/L 5
CPK 10 – 2000 U/L 0.17 – 33.40 μ Kat/L 4
GGT 10 – 1200 U/L 0.17 – 20.04 μ Kat/L 5
GOT/AST 10 – 1000 U/L 0.17 – 16.70 μ Kat/L 4
GPT/ALT 10 – 1000 U/L 0.17 – 16.70 μ Kat/L 4
LAP 10 – 500 U/L 0.17 – 8.35 μ Kat/L 4
LDH 50 – 900 U/L 0.84 – 15.03 μ Kat/L 2
LIP 20 – 1000 U/L 0.33 – 16.70 μ Kat/L 5
General chemistry ALB 1.0 – 6.0 g/dL 10 – 60 g/L 6
BUN 5.0 – 140.0 mg/dL 1.79 – 49.98 mmol/L 4
Ca 4.0 – 16.0 mg/dL 1.00 – 4.00 mmol/L 4
CRE 0.2 – 24.0 mg/dL 18 – 2122 μmol/L 5
DBIL 0.1 – 16.0 mg/dL 2 – 274 μmol/L 5
GLU 10 – 600 mg/dL 0.6 – 33.3 mmol/L 6
HDL-C 10 – 110 mg/dL 0.26 – 2.84 mmol/L 6
IP 0.5 – 15.0 mg/dL 0.16 – 4.84 mmol/L 5
Mg 0.2 – 7.0 mg/dL 0.08 – 2.88 mmol/L 4.5
NH3 10 – 500 μg /dL 7 – 357 μmol/L 2
TBIL 0.2 – 30.0 mg/dL 3 – 513 μmol/L 6
TCHO 50 – 450 mg/dL 1.29 – 11.64 mmol/L 6
TCO2 5 – 40 mmol/L 5 – 40 mmol/L 5
TG 10 – 500 mg/dL 0.11 – 5.65 mmol/L 4
TP 2.0 – 11.0 g/dL 20 – 110 g/L 6
UA 0.5 – 18.0 mg/dL 30 – 1071 μmol/L 4
Electrolytes Na 75 – 250 mEq/L 75 – 250 mmol/L 1
K 1.0 – 14.0 mEq/L 1.0 – 14.0 mmol/L
Cl 50 – 175 mEq/L 50 – 175 mmol/L
Immunological test CRP 0.3 – 7.0 mg/dL 3 – 70 mg/L 5
Comprehensive S-panel TP, ALB, ALP, GLU, TBIL, IP, TCHO, GGT, GPT/ALT, Ca, CRE, BUN
Small Screening S-panel ALP, TBIL, GGT, GPT/ALT, CRE, GOT/AST
  • * There are parameters which may not be available in your area. For details please contact your local distributor.
  • *1 Unit (A) and (B) is available

Calculations

Calculated Parameter

Indication

Unit

Equation

LDL Cholesterol

LDL

mg/dL

LDL-C = TCHO value - (HDL-C vlaue + TG value/5)

mmol/L

LDL-C = TCHO value - (HDL-C value + TG value/2.2)

non-HDL Cholesterol

non-HDL

mg/dL or mmol/L

non-HDL = TCHO value - HDL-C value

Globulin

GLOB

g/dL or g/L

GLOB = TP value - ALB value

Albumin/Globulin ratio

ALB/GLOB

-

ALB/GLOB = ALB value / (TP value - ALB value)

BUN/Creatinine ratio

BUN/CRE

-

BUN/CRE = BUN value / CRE value

Anion Gap

Anion Gap

mEq/L or mmol/L

Anion Gap = Na value - (Cl value + TCO2 value)

 

Main specifications

Measurement test

Colorimetry 28 tests
Electrolytes 3 tests

Throughput

Colorimetry 120 test/hour
Combined 128 test/hour

Number of sample rack

1

Number of incubator cell

Colorimetry 12, Electrolytes 1

Measurement time

Colorimetry 2 to 6 minutes/test,
Electrolytes 1 minute/3 tests (Na-K-Cl)

Sample type

Plasma, Serum, Whole blood*2

Sample volume

Colorimetry 10μL/test,
Electrolytes 50μL/3 tests (Na-K-Cl), CRP 5μL/test

Data transmission to PC

USB 2.0 or RS-232C Serial
D-Sub 9 pin -9 pin cross cable

Data print

Thermal Printer

Electrical requirements

AC 100-240V, 50/60Hz, 2.5-1.1A

Dimensions

470 (W) 5 360 (D) 5 420 (H) mm

Weight

NX500 Approx. 25kg, NX500i Approx. 24kg

Operating temperature

15 to 32˚C (59 to 89F)

Operating humidity

30 to 80%RH

  • *2 NH3-W: Whole blood only    NH3-P: Plasma only
  •  Na-K-Cl: Plasma, Serum, Whole blood
  •  Other test items: Plasma, Serum

DRI-CHEM  NX500 Series

  NX500 NX500i
Electrolyte tests
Plasma Filter Function -
Automatic dilution
  • *DRI-CHEM NX500(Product:FUJI DRI-CHEM NX500/FUJI DRI-CHEM NX500i)
  • Please contact your local distributor for availability.

Operator ID Editor Kit

Operator ID Editor tool software (for PC) and a USB stick (for data transfer between PC and NX500) for registration and editing operator ID